In the table below you can find the Qubino Mini Dimmer parameters numbers, possible values and its default values. For more details you can check the extended user manual - parameters chapter.
Num | Parameter description | Byte | Default | Values |
1 | In-wall Switch type Load (output) to control l1 | 1 | 0 | 0, 1 |
5 | Working mode | 1 | 0 | 0, 1 |
11 | Turn Load (output) Off Automatically with Timer | 2 | 0 | 1 - 32536 |
12 | Turn Load (output) On Automatically with Timer | 2 | 0 | 1 - 32536 |
21 | Enable/Disable the Double click function | 1 | 0 | 0, 1 |
30 | Restore on/off status for (output) load after power failure | 1 | 0 | 0, 1 |
40 | Watt Power Consumption Reporting Threshold for (output) load | 1 | 10 | 0 - 100 |
42 | Watt Power Consumption Report Time Threshold for (output) load | 2 | 0 | 30 - 32767 |
60 | Minimum dimming value | 1 | 0 | 00 - 098 |
61 | Maximum dimming value | 1 | 99 | 02 - 099 |
65 | Dimming time when key pressed (soft on/off) | 1 | 1 | 1 - 127 |
66 | Dimming time when key hold | 2 | 3 | 1 - 127 |
67 | Ignore start level | 1 | 0 | 0, 1 |
68 | Dimming duration | 1 | 0 | 1 - 127 |
70 | Overload safety switch | 2 | 200 | 0 - 200 |
71 | Calibration trigger | 1 | 0 | 0,1,2 |
72 | Calibration status (read only) | 1 | 0 | 0, 1 |
73 | Alarm/Notification events | 1 | 0 | 0,1,2,3 |
74 | Alarm/Notification time interval (dependent on parameter 73) | 1 | 10 | 1 - 125 |