Exclusion of a Qubino Flush device from a Z-Wave network
Exclusion of the Qubino Smart Meter or Qubino 3 Phase Smart Meter from a Z-Wave network
Exclusion of the Qubino DIN Dimmer from a Z-Wave network
Exclusion of the Qubino Flush RGBW Dimmer from a Z-Wave network
Exclusion of the Qubino Smart Plug from a Z-Wave network
Exclusion of the Luxy Smart Switch from a Z-Wave network
Removal of a Qubino Flush device from a Z-Wave network (Z-Wave exclusion)
- Connect the device to the power supply if not already connected
- Make sure the device is within direct range of your Z-Wave gateway (hub) or use a handheld Z-Wave remote to perform exclusion
- Enable add/remove mode on your Z-Wave gateway (hub)
- Toggle the switch connected to the I1 terminal 3 times within 3 seconds (The device has to get On/Off signal 3 times, meaning 3 times push of the push button or with the normal button On / Off / On / Off / On / Off)
OR
If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 3 and 5 seconds - The device will be removed from your network but any custom configuration parameters will not be erased
Removal of the Qubino Smart Meter or 3 Phase Smart Meter from a Z-Wave network (Z-Wave exclusion)
- Connect the device to the power supply if not already connected
- Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held Z-Wave remote to perform exclusion
- Enable add/remove mode on your Z-Wave gateway (hub)
- Press and hold the S service button between 0.2 and 3 seconds
- Exclusion with the S service button is not limited by time
- The device will be removed from your network but custom configuration parameters will not be erased. Wait at least 30 seconds before adding the device back to a network.
Removal of the Qubino DIN Dimmer from a Z-Wave network (Z-Wave exclusion)
- Connect the device to the power supply if not already connected
- Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held Z-Wave remote to perform exclusion
- Enable add/remove mode on your Z-Wave gateway (hub)
- Toggle the switch connected to the I1 terminal 3 times within 3 seconds
OR - Press and hold the S (Service) button between 2 and 6 seconds
- The device will be removed from your network but any custom configuration parameters will
not be erased
Removal of the Qubino Flush RGBW Dimmer from a Z-Wave network (Z-Wave exclusion)
- Connect the device to the power supply if not already connected
- Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held Z-Wave remote to perform exclusion
- Enable add/remove mode on your Z-Wave gateway (hub)
- Press and release the S button 3 times within 2 seconds
- After exclusion device will automatically attempt to re-include in the next 2 minutes.
- The device will be removed from your network but any custom configuration parameters will not be erased
Removal of the Qubino Smart Plug from a Z-Wave network (Z-Wave exclusion)
- Connect the device to the power supply if not already connected
- Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held Z-Wave remote to perform exclusion
- Enable add/remove mode on your Z-Wave gateway (hub)
- Press and hold the Service button S from 2 to 6 seconds (with holding the S button for the interval between 2 and 6 seconds you put the device in EXCLUSION MODE)
- Exclusion with the S service button is not limited by time The device will be removed from your network, but any custom configuration parameters will not be erased
Removal of a Luxy Smart Switch device from a Z-Wave network (Z-Wave exclusion)
|
- Connect the device to the power supply if not already connected
- Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held Z-Wave remote to perform exclusion
- Enable add/remove mode on your Z-Wave gateway (hub)
- Press once on button 3 – right. One press on button 4 – down for enabling full white. When full white is enabled, press, and hold button 3 – right for 5 seconds. After 5 seconds, the device starts flashing red 1 second ON, 0.5 second OFF. Once the device loses node ID (after 10 seconds), it stops flashing and turns full red. The procedure is always available.